Warnings
--------
Changing parameters when the inverters are in operation should be done carefully. The
modification of parameters can restart the corresponding algorithm inside the inverter. For
example, the change of a delay can restart the timer attached to it.

When you are using the *RCC* remote control, the *Xtender* inverter/charger, *VarioTrack* and
*VarioString MPPT* solar chargers store their parameter values in a non-volatile flash memory.
Because of the endurance of this memory, the number of writes on a single parameter is only
**guaranteed for 1000 write operations**.
To allow the cyclic write of parameters without count limit, we suggest you to write the
parameters in RAM only
"""

from struct import pack, unpack
from datetime import datetime
from umodbus.client.serial import rtu
from umodbus.exceptions import *
from xcom485i.addresses import Addresses
import logging

logger = logging.getLogger(__name__)


[docs]class Xcom485i: """ This class act as a *Modbus* master in order to communicate with the *Xcom-485i* gateway (slave) Attributes ---------- serial_port: serial.Serial Serial port used for communication with the gateway addresses: xcom485i.addresses.Addresses Instance of Addresses class grouping all the ones accessible from the Xcom-485i """
[docs] def __init__(self, serial_port, offset=0, debug=False): """ serial device must be configured with :\n - EVEN parity\n - 1 start bit\n - 8 data bits, LSB first\n - 1 parity bit (Even)\n - 1 stop bit\n - timeout 1 second\n Parameters ---------- serial_port Instance of serial module offset The address offset as defined with the dip-switches debug: boolean Activate debug traces for tx/rx frames """ self.serial_port = serial_port if debug is True: logging.basicConfig(level=logging.DEBUG) self.addresses = Addresses(offset)
def __del__(self): """ Explicit destructor Ensure to close serial device Returns ------- None """ self.serial_port.close()
[docs] def read_parameter(self, slave_id, address): """ Read a parameter from a targeted device as a float. Note ----- All parameters accessible from *RCC* can also be accessed with the *Modbus* protocol.\n It is possible to read the actual value of the parameter from Flash, but also the minimum and the maximum value.\n To distinguish between these, we use a different register address offset as explained below:\n - read value from flash : offset is 0 (READ_PARAM_FLASH_OFFSET)\n - read min allowed value : offset is 2000 (READ_PARAM_MIN_OFFSET)\n - read max allowed value : offset is 4000 (READ_PARAM_MAX_OFFSET)\n Parameters ---------- slave_id: int Slave identifier number (targeted device) address: int Register starting address, see Studer Modbus RTU Appendix for the complete list of accessible register per device Returns ------- float parameter read Example -------- .. code-block:: python # Read parameter 1107, Maximum current of AC source, (Modbus register 14) from the first Xtender # Run this example within the 'examples/' folder using 'python ex_read_param.py' from a CLI # after installing xcom485i package with 'pip install xcom485i' import serial from xcom485i.client import Xcom485i SERIAL_PORT_NAME = 'COM4' # your serial port interface name SERIAL_PORT_BAUDRATE = 9600 # baudrate used by your serial interface DIP_SWITCHES_ADDRESS_OFFSET = 0 # your modbus address offset as set inside the Xcom485i device if __name__ == "__main__": try: serial_port = serial.Serial(SERIAL_PORT_NAME, SERIAL_PORT_BAUDRATE, parity=serial.PARITY_EVEN, timeout=1) except serial.serialutil.SerialException as e: print("Check your serial configuration : ", e) else: xcom485i = Xcom485i(serial_port, DIP_SWITCHES_ADDRESS_OFFSET, debug=True) # read actual value stored into flash memory read_value = xcom485i.read_parameter(xcom485i.addresses.xt_1_device_id, 14 + xcom485i.addresses.read_param_flash_offset) print('read_value:', read_value) # read minimum value of this parameter read_value = xcom485i.read_parameter(xcom485i.addresses.xt_1_device_id, 14 + xcom485i.addresses.read_param_min_offset) assert read_value == 2.0 # only for 1107 parameter print('read_min_value:', read_value) # read maximum value of this parameter read_value = xcom485i.read_parameter(xcom485i.addresses.xt_1_device_id, 14 + xcom485i.addresses.read_param_max_offset) assert read_value == 50.0 # only for 1107 parameter print('read_max_value:', read_value) """ message = rtu.read_holding_registers(slave_id=slave_id, starting_address=address, quantity=2) logger.debug("-> Transmit ADU : 0x%s", str(bytes(message).hex())) try: response = rtu.send_message(message, self.serial_port) except (ValueError, KeyError) as e: logger.error( "--> Please match your configurations and the values set with the dip-switches on the device: ", e) except ModbusError as e: logger.error("--> Modbus error : ", e) else: ba = pack('>HH', response[0], response[1]) float_response = unpack('>f', ba)[0] logger.debug("<- Receive data : 0x%s", str(ba.hex())) return float_response
[docs] def read_time(self, slave_id): """ Read the system time from a targeted installation. Note ----- The system time is available at the address 0 of the device system.\n The time registers are accessible separetely if needed by using the correct address and length.\n Here is the list of time registers:\n - 0 -> Microsecond\n - 1 -> Second\n - 2 -> Minute\n - 3 -> Hour\n - 4 -> Weekday\n - 5 -> Day\n - 6 -> Month\n - 7 -> Year (format 2022 = 22)\n Parameters ---------- slave_id: int Slave identifier number (targeted device) Returns ------- datetime actual system time Example -------- .. code-block:: python # Read the system time # Run this example within the 'examples/' folder using 'python ex_read_time.py' from a CLI after installing # xcom485i package with 'pip install xcom485i' import serial from xcom485i.client import Xcom485i SERIAL_PORT_NAME = 'COM4' # your serial port interface name SERIAL_PORT_BAUDRATE = 9600 # baudrate used by your serial interface DIP_SWITCHES_ADDRESS_OFFSET = 0 # your modbus address offset as set inside the Xcom485i device if __name__ == "__main__": try: serial_port = serial.Serial(SERIAL_PORT_NAME, SERIAL_PORT_BAUDRATE, parity=serial.PARITY_EVEN, timeout=1) except serial.serialutil.SerialException as e: print("Check your serial configuration : ", e) else: xcom485i = Xcom485i(serial_port, DIP_SWITCHES_ADDRESS_OFFSET, debug=True) # read actual value stored into flash memory read_value = xcom485i.read_time(xcom485i.addresses.system_device_id) print('Read time:', read_value) """ message = rtu.read_holding_registers(slave_id=slave_id, starting_address=0, quantity=8) logger.debug("-> Transmit ADU : 0x%s", str(bytes(message).hex())) try: response = rtu.send_message(message, self.serial_port) except (ValueError, KeyError) as e: logger.error( "--> Please match your configurations and the values set with the dip-switches on the device: ", e) except ModbusError as e: logger.error("--> Modbus error : ", e) else: return datetime(response[7], response[6], response[5], response[3], response[2], response[1], response[0]*1000)
[docs] def write_parameter(self, slave_id, address, value): """ Write a parameter value into a targeted device. Note ----- All parameters accessible from *RCC* can also be accessed with the *Modbus* protocol.\n In the *Xtender* system, it is possible to write a value in Flash (and RAM) or in RAM only.\n To distinguish between both, we use a different register address offset as explained below:\n - write value into FLASH and RAM : offset is 0 (WRITE_PARAM_FLASH_RAM)\n - write value into RAM only : offset is 6000 (WRITE_PARAM_RAM_ONLY)\n Parameters ---------- slave_id Slave identifier number (targeted device) address Register starting address, see *Studer Modbus RTU Appendix* for the complete list of accessible register per device value The value to write Returns ------- int Quantity of written registers (must be 2) Example -------- .. code-block:: python # Write parameter 1107 in RAM only, Maximum current of AC source, (Modbus register 14) # from the first Xtender # Run this example within the 'examples/' folder using 'python ex_write_param.py' from a CLI # after installing xcom485i package with 'pip install xcom485i' import serial from xcom485i.client import Xcom485i SERIAL_PORT_NAME = 'COM4' # your serial port interface name SERIAL_PORT_BAUDRATE = 9600 # baudrate used by your serial interface DIP_SWITCHES_ADDRESS_OFFSET = 0 # your modbus address offset as set inside the Xcom485i device if __name__ == "__main__": try: serial_port = serial.Serial(SERIAL_PORT_NAME, SERIAL_PORT_BAUDRATE, parity=serial.PARITY_EVEN, timeout=1) except serial.serialutil.SerialException as e: print("Check your serial configuration : ", e) else: xcom485i = Xcom485i(serial_port, DIP_SWITCHES_ADDRESS_OFFSET, debug=True) value = 8 # 8 [A] echo = xcom485i.write_parameter(xcom485i.addresses.xt_1_device_id, 14 + xcom485i.addresses.write_param_ram_only, value) # a value of 2 is expected on write action, represent the number of registers written assert echo == 2 print('echo:', echo) """ ba = pack('>f', value) registers = unpack('>HH', ba) message = rtu.write_multiple_registers(slave_id=slave_id, starting_address=address, values=registers) logger.debug("-> Transmit ADU : 0x%s", str(bytes(message).hex())) try: response = rtu.send_message(message, self.serial_port) except (ValueError, KeyError) as e: logger.error( "--> Please match your configurations and the values set with the dip-switches on the device: ", e) except ModbusError as e: logger.error("--> Modbus error : ", e) else: logger.debug("<- Receive data : 0x%s", str(response)) return response
[docs] def write_time(self, slave_id, value): """ Write the time of a targeted installation. Note ----- It is only possible to set the time and date by writting all registers at the same time.\n Here is the list of time registers:\n - 0 -> Microsecond\n - 1 -> Second\n - 2 -> Minute\n - 3 -> Hour\n - 4 -> Weekday\n - 5 -> Day\n - 6 -> Month\n - 7 -> Year (format 2022 = 22)\n Parameters ---------- slave_id Slave identifier number (targeted device) value The new datetime to write Returns ------- int Quantity of written registers (must be 8) Example -------- .. code-block:: python # Write the system time # Run this example within the 'examples/' folder using 'python ex_write_time.py' from a CLI after installing # xcom485i package with 'pip install xcom485i' import serial from xcom485i.client import Xcom485i from datetime import datetime SERIAL_PORT_NAME = 'COM4' # your serial port interface name SERIAL_PORT_BAUDRATE = 9600 # baudrate used by your serial interface DIP_SWITCHES_ADDRESS_OFFSET = 0 # your modbus address offset as set inside the Xcom485i device if __name__ == "__main__": try: serial_port = serial.Serial(SERIAL_PORT_NAME, SERIAL_PORT_BAUDRATE, parity=serial.PARITY_EVEN, timeout=1) except serial.serialutil.SerialException as e: print("Check your serial configuration : ", e) else: xcom485i = Xcom485i(serial_port, DIP_SWITCHES_ADDRESS_OFFSET, debug=True) # current date and time current_dt = datetime.now() print(current_dt) echo = xcom485i.write_time(xcom485i.addresses.system_device_id, current_dt) assert echo == 8 # a value of 2 is expected on write action, represent the number of registers written print('echo:', echo) """ registers = [int(value.microsecond / 1000), value.second, value.minute, value.hour, value.weekday(), value.day, value.month, value.year] message = rtu.write_multiple_registers(slave_id=slave_id, starting_address=0, values=registers) logger.debug("-> Transmit ADU : 0x%s", str(bytes(message).hex())) try: response = rtu.send_message(message, self.serial_port) except (ValueError, KeyError) as e: logger.error( "--> Please match your configurations and the values set with the dip-switches on the device: ", e) except ModbusError as e: logger.error("--> Modbus error : ", e) else: logger.debug("<- Receive data : 0x%s", str(response)) return response
[docs] def read_info(self, slave_id, address): """ Read a user info from a targeted device as a float. Note ----- The available user information is the same as the values that can be chosen to be displayed on the *RCC*. This user information gives the current state of the system. The user information can not be modified and their values change during the operation of the system. Parameters ---------- slave_id Slave identifier number (targeted device) address Register starting address, see *Studer Modbus RTU Appendix* for the complete list of accessible register per device Returns ------- float User info read Example -------- .. code-block:: python # Read user info 3001, Battery temperature, (Modbus register 2) from the first Xtender # Run this example within the 'examples/' folder using 'python ex_read_info.py' from a CLI # after installing xcom485i package with 'pip install xcom485i' import serial from xcom485i.client import Xcom485i SERIAL_PORT_NAME = 'COM4' # your serial port interface name SERIAL_PORT_BAUDRATE = 9600 # baudrate used by your serial interface DIP_SWITCHES_ADDRESS_OFFSET = 0 # your modbus address offset as set inside the Xcom485i device if __name__ == "__main__": try: serial_port = serial.Serial(SERIAL_PORT_NAME, SERIAL_PORT_BAUDRATE, parity=serial.PARITY_EVEN, timeout=1) except serial.serialutil.SerialException as e: print("Check your serial configuration : ", e) else: xcom485i = Xcom485i(serial_port, DIP_SWITCHES_ADDRESS_OFFSET, debug=True) read_value = xcom485i.read_info(xcom485i.addresses.xt_1_device_id, 2) print('read_value:', read_value) """ message = rtu.read_input_registers(slave_id=slave_id, starting_address=address, quantity=2) logger.debug("-> Transmit ADU : 0x%s", str(bytes(message).hex())) try: response = rtu.send_message(message, self.serial_port) except (ValueError, KeyError) as e: logger.error( "--> Please match your configurations and the values set with the dip-switches on the device: ", e) except ModbusError as e: logger.error("--> Modbus error : ", e) else: ba = pack('>HH', response[0], response[1]) float_response = unpack('>f', ba)[0] logger.debug("<- Receive data : 0x%s", str(ba.hex())) return float_response
[docs] def read_input_registers(self, slave_id, address, quantity): """ Get raw data from input registers. Parameters ---------- slave_id Slave identifier number (targeted device) address Register starting address quantity Quantity of registers to read Returns ------- bytes Raw data from targeted registers """ message = rtu.read_input_registers(slave_id=slave_id, starting_address=address, quantity=quantity) logger.debug("-> Transmit ADU : 0x%s", str(bytes(message).hex())) try: response = rtu.send_message(message, self.serial_port) except (ValueError, KeyError) as e: logger.error( "--> Please match your configurations and the values set with the dip-switches on the device: ", e) except ModbusError as e: logger.error("--> Modbus error : ", e) else: hex_response = ' '.join(hex(x) for x in response) logger.debug("<- Receive data : %s", str(hex_response)) return response
[docs] def pending_message_count(self): """ Get the number of currently pending messages stored into the gateway, by reading the content of the 0x0000 input register. Note ----- Within the *Xtender* system, any device (*Xtender*, *VarioTrack*, *VarioString*, *BSP*, *Xcom-CAN BMS*) can send messages. These messages are displayed on the *RCC* and also available on the *Studer Portal* whenever the installation is connected to the Internet. Returns ------- int The number of pending messages (up to 128) See also -------- Xcom485i.message_registers """ return self.read_input_registers(self.addresses.gateway_device_id, 0, 1)[0]
[docs] def message_registers(self): """ Read pending messages stored into the gateway. Note ----- Once a message is read, it is deleted inside the *Xcom-485i*, so use `Xcom485i.pending_message_count` in order to know how many messages are pending and iteratively call this function to retrieve all messages. The response is like :\n - Input Register 0 (@ 0x0001)| 2 bytes | Device source\n - Input Register 1 (@ 0x0002)| 2 bytes | Message ID\n - Input Register 2 (@ 0x0003)| 2 bytes | Optional value Most significant word\n - Input Register 3 (@ 0x0004)| 2 bytes | Optional value Least significant word\n Returns ------- bytes Content of Input Register 0, 1, 2, 3 Example -------- .. code-block:: python # Read all pending messages stored into the gateway # Run this example within the 'examples/' folder using 'python ex_read_messages.py' from a CLI # after installing xcom485i package with 'pip install xcom485i' import serial from xcom485i.client import Xcom485i SERIAL_PORT_NAME = 'COM4' # your serial port interface name SERIAL_PORT_BAUDRATE = 9600 # baudrate used by your serial interface DIP_SWITCHES_ADDRESS_OFFSET = 0 # your modbus address offset as set inside the Xcom485i device if __name__ == "__main__": try: serial_port = serial.Serial(SERIAL_PORT_NAME, SERIAL_PORT_BAUDRATE, parity=serial.PARITY_EVEN, timeout=1) except serial.serialutil.SerialException as e: print("Check your serial configuration : ", e) else: xcom485i = Xcom485i(serial_port, DIP_SWITCHES_ADDRESS_OFFSET, debug=True) # always check the number of pending messages pending_message_count = xcom485i.pending_message_count() print('pending_message_count:', pending_message_count) for _ in range(pending_message_count): message_registers = xcom485i.message_registers() print('Message N°:', _) print("\t device source: ", message_registers[0]) print("\t message id: ", message_registers[1]) print("\t optionnal most significant word: ", message_registers[2]) print("\t optionnal least significant word: ", message_registers[3]) """ return self.read_input_registers(self.addresses.gateway_device_id, 1, 4)